Thermomass Press Release | December 9, 2011

Article tools: Share:

Thermomass Achieves 4-Hour ASTM E-119 Fire Rating

Results mark the first and only successful 4-hour ASTM E-119 mark for an integrally insulated sandwich wall using an energy efficient FRP wythe connectors.

Thermomass, the leading manufacturer of building insulation systems for the concrete industry, is proud to announce the successful completion of the ASTM E-119 fire test.

The fire test was conducted on a sandwich wall panel consisting of a 2-in exterior wythe of concrete, 2-in insulation core, and a 5-in interior wythe of concrete. The interior wythe was loaded to 4,000 pounds per foot gravity load and exposed to fire for a duration of 4-hours, with temperatures reaching 2,000 °F.

According to Darryl Dixon, Director of Technical Services at Thermomass, “During the 4-hour test, the temperature on the exterior wythe of concrete increased by only 130 °F, which is only 50% of the allowed temperature increase per ASTM E-119.”

The successful 4-hour mark is the first and only ASTM E-119 test on an integrally insulated sandwich wall using an energy efficient FRP wythe connector.

Venkatesh Seshappa, PE, SE, Director of Engineering at Thermomass noted, “The ASTM E-119 test expands on the ICC-ESR on our MC/MS Series connectors, and provides an unprecedented level of testing achievements for the concrete sandwich wall panel industry.”

 